Description
IFW is a mechanical switch for the detection and confirmation of liquid
flow. The flow body houses a diaphragm responsive to flow rate. A
connected rod and lever mechanism triggers a micro switch at a manually
adjustable set point. An optiional light, either neon (VAC) or LED (VDC),
can indicate operation. Compatible liquids must be non-corrosive to the
brass and copper alloy wetted parts and NBR or optional FKM diaphram.
Wiring method can be normally open or closed with a range of voltages. A
terminal box and CE compliance are also optional.
– Flow ranges (lpm): 1-10, 10-20, 20-50
– Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4
– Temperature rating (°C): -5 to 60
– Operating pressure (MPa): 0.1 to 0.6
– Withstand voltage: 1500 VAC (one minute)
Download IFW Datasheet by click the link Datasheet.