Description
Siemens 3VA1112-3FE46-0AA0 Circuit breaker 3VA1 IEC Frame 160 Switching capacity class N Icu=25 kA @ 415 V 4-pole, system protection TM220, ATFM, In=125 A Overload protection Ir=88 A…125 A short-circuit protection Ii=10 x In N-conductor protection 50% Terminal connection
Version | Classification | |
eClass | 5.1 | 27-37-04-09 |
eClass | 6 | 27-37-04-09 |
eClass | 7.1 | 27-37-04-09 |
eClass | 8 | 27-37-04-09 |
eClass | 9 | 27-37-04-09 |
eClass | 9.1 | 27-37-04-09 |
ETIM | 4 | EC000228 |
ETIM | 5 | EC000228 |
ETIM | 6 | EC000228 |
Overview
The new 3VA circuit breakers set new standards in terms of flexibility and variety of modular accessories. Standardized accessories suitable for use with several sizes of circuit breaker from all the 3VA ranges help to cut costs and save installation time.
3VA1 molded case circuit breakers
The new 3VA1 molded case circuit breakers reliably perform all the tasks required for line protection and starter protection.
Features
The key features of the 3VA1 series are:
- Compact design
- Depending on size: 1-pole to 4-pole versions
- Depending on size: Breaking capacity of 16 kA … 70 kA at 415 V, 3 or 4-pole breakers and 36 kA at 240 V,1-pole breakers
- Fixed version, plug-in version
- Thermal-magnetic trip units
- AC/DC applications
- No derating up to +50 °C
- Modular and easy-to-fit internal accessories with diverse functions
- Uniform accessories platform across all 3VA molded case circuit breakers
3VA2 molded case circuit breakers
The new 3VA2 molded case circuit breakers reliably perform all the tasks required for line protection, generator protection, motor protection and starter protection.
This series has been developed for applications with inceased requirements:
- Increased breaking capacity
- Very good selective protection response
- Integrated measurement function
- Connection to a fieldbus communication system
Features
The most important features of the 3VA2 series are:
- Compact design
- 3 and 4-pole versions
- Four breaking capacity classes from 55 kA … 150 kA
- Fixed-mounting, plug-in technology, draw-out technology
- Depending on size: Selective protection response at rated operating current interval 1: 2.5
- Electronic Trip Units
- Retrofit communication for ETU 5-series and 8-series
- Depending on the ETU: Integrated measurement function
- AC applications
- No derating up to +50 °C
- Modular and easy-to-fit internal accessories with diverse functions
- Uniform accessories platform across all 3VA molded case circuit breakers