Description
SINAMICS G110-CPM110 AC Drive, with integr. filter B 200-240V1AC+10/-10% 47-63Hz RS485 interface (USS protocol) CT: 0.12 kW; VT: 0.12 kW CT overload: 150% 60s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation Ambient temperature -10+50 °C without BOP without analog input6SL3211-0KB11-2BB1_datasheet_en
Overview of G110 AC Drive
SINAMICS G110 is an inverter with basic functions for a wide range of industrial drive applications with variable speeds.
The extremely compact SINAMICS G110 inverter operates with voltage-frequency control from 200 V to 240 V on single-phase line supply systems.
It is the ideal “price-conscious” inverter solution in the lower power range of the SINAMICS product family.
The following line-side power components are available for SINAMICS G110 inverters:
- EMC filters
- Line reactors
- Fuses
- Circuit breaker
The accessories listed below are also available:
- Operator panel
- Mounting accessories
- Commissioning tool
Benefits
- Simple installation, configuration, and commissioning
- Robust EMC design
- Extensive parameter range enables configurations for a wide range of applications
- Simple cable connection
- Scalable functionality with analog and USS versions
- Quiet motor operation as a result of the high pulse frequency
- Status information and alarms via the optional BOP (Basic Operator Panel)
- Rapid copying of parameters via the optional BOP
- External options for PC communication and BOP
- Fast response time of the digital inputs with a high degree of reproducibility for applications demanding fast responses
- Precise setpoint input using a high-resolution 10-bit analog input (analog versions only)
- LED for status information
- Variants with integrated EMC filter class A or B
- DIP switches for easy adaptation to 50 Hz or 60 Hz applications
- DIP switches for simple bus termination for the USS version (RS485)
- Bus-capable serial RS485 interface (USS versions only) enables integration into a networked drive system
- 2/3-wire method (pulsed/maintained signals) for universal control via digital inputs
- Adjustable lower voltage limit for the DC link to ensure controlled motor braking if the power fails
Accessories (overview)
- BOP operator panel
- Adapter for mounting on DIN rails (frame sizes FSA and FSB)
- PC inverter connection kit
- STARTER commissioning tool
Line-side power components (overview)
- EMC filter, class B with low leakage currents
(additionally available for inverters with integrated filter) - EMC filter, class B
(additionally available for inverters with integrated filter) - Line reactors
International standards
- Fulfills the requirements of the EU low-voltage guideline
- CE marking
- Certified to UL and cUL
- C-Tick
Technical specifications
Referring to the rated output current, most 2-pole to 6-pole low-voltage motors are supported, e.g. the motor series 1LE1. The rated power represents a benchmark only. For a description of the overload performance, please refer to the general technical specifications of the Controlled Power Modules.
Power | Rated input current (at 230 V) | Rated output current | Frame size | Version | SINAMICS G110 without filter |
SINAMICS G110 with integrated filter |
||||
---|---|---|---|---|---|---|---|---|---|---|
kW | hp | A | A | (Frame size) | Article No. | Article No. | Filter class 1) With use of shielded cables with a max. cable length of |
|||
5 m (16 ft) | 10 m (33 ft) | 25 m (82 ft) | ||||||||
0.12 | 0.16 | 2.3 | 0.9 | FSA | Analog | 6SL3211-0AB11-2UA1 | 6SL3211-0AB11-2BA1 | B | A 2) | 2) |
USS | 6SL3211-0AB11-2UB1 | 6SL3211-0AB11-2BB1 | B | A 2) | 2) | |||||
Analog (with flat heat sink) |
6SL3211-0KB11-2UA1 | 6SL3211-0KB11-2BA1 | B | A 2) | 2) | |||||
USS (with flat heat sink) |
6SL3211-0KB11-2UB1 | 6SL3211-0KB11-2BB1 | B | A 2) | 2) | |||||
0.25 | 0.33 | 4.5 | 1.7 | FSA | Analog | 6SL3211-0AB12-5UA1 | 6SL3211-0AB12-5BA1 | B | A 2) | 2) |
USS | 6SL3211-0AB12-5UB1 | 6SL3211-0AB12-5BB1 | B | A 2) | 2) | |||||
Analog (with flat heat sink) |
6SL3211-0KB12-5UA1 | 6SL3211-0KB12-5BA1 | B | A 2) | 2) | |||||
USS (with flat heat sink) |
6SL3211-0KB12-5UB1 | 6SL3211-0KB12-5BB1 | B | A 2) | 2) | |||||
0.37 | 0.5 | 6.2 | 2.3 | FSA | Analog | 6SL3211-0AB13-7UA1 | 6SL3211-0AB13-7BA1 | B | A 2) | 2) |
USS | 6SL3211-0AB13-7UB1 | 6SL3211-0AB13-7BB1 | B | A 2) | 2) | |||||
Analog (with flat heat sink) |
6SL3211-0KB13-7UA1 | 6SL3211-0KB13-7BA1 | B | A 2) | 2) | |||||
USS (with flat heat sink) |
6SL3211-0KB13-7UB1 | 6SL3211-0KB13-7BB1 | B | A 2) | 2) | |||||
0.55 | 0.75 | 7.7 | 3.2 | FSA | Analog | 6SL3211-0AB15-5UA1 | 6SL3211-0AB15-5BA1 | B | A 2) | 2) |
USS | 6SL3211-0AB15-5UB1 | 6SL3211-0AB15-5BB1 | B | A 2) | 2) | |||||
Analog (with flat heat sink) |
6SL3211-0KB15-5UA1 | 6SL3211-0KB15-5BA1 | B | A 2) | 2) | |||||
USS (with flat heat sink) |
6SL3211-0KB15-5UB1 | 6SL3211-0KB15-5BB1 | B | A 2) | 2) | |||||
0.75 | 1 | 10 | 3.9 (at 40 °C (104 °F)) |
FSA | Analog | 6SL3211-0AB17-5UA1 | 6SL3211-0AB17-5BA1 | B | A 2) | 2) |
USS | 6SL3211-0AB17-5UB1 | 6SL3211-0AB17-5BB1 | B | A 2) | 2) | |||||
Analog (with flat heat sink) |
6SL3211-0KB17-5UA1 | 6SL3211-0KB17-5BA1 | B | A 2) | 2) | |||||
USS (with flat heat sink) |
6SL3211-0KB17-5UB1 | 6SL3211-0KB17-5BB1 | B | A 2) | 2) | |||||
1.1 | 1.5 | 14.7 | 6 | FSB | Analog | 6SL3211-0AB21-1UA1 | 6SL3211-0AB21-1AA1 | B | A 2) | A 2) |
USS | 6SL3211-0AB21-1UB1 | 6SL3211-0AB21-1AB1 | B | A 2) | A 2) | |||||
1.5 | 2 | 19.7 | 7.8 (at 40 °C (104 °F)) |
FSB | Analog | 6SL3211-0AB21-5UA1 | 6SL3211-0AB21-5AA1 | B | A 2) | A 2) |
USS | 6SL3211-0AB21-5UB1 | 6SL3211-0AB21-5AB1 | B | A 2) | A 2) | |||||
2.2 | 3 | 27.2 | 11 | FSC | Analog | 6SL3211-0AB22-2UA1 | 6SL3211-0AB22-2AA1 | B | A 2) | A 2) |
USS | 6SL3211-0AB22-2UB1 | 6SL3211-0AB22-2AB1 | B | A 2) | A 2) | |||||
3 | 4 | 35.6 | 13.6 (at 40 °C (104 °F)) |
FSC | Analog | 6SL3211-0AB23-0UA1 | 6SL3211-0AB23-0AA1 | B | A 2) | A 2) |
USS | 6SL3211-0AB23-0UB1 | 6SL3211-0AB23-0AB1 | B | A 2) | A 2)
|