ST-10D DC (Direct Current) Spark Tester Insulation Detector Of Cable is a recommended tool for detection cable surface defect and for spark test for wire and cable, the diameter of cable will be detected reach up to 10mm. The DC high voltage tester with steady voltage output, high sensitivity, adaptability, easy to us, and high reliability, it can be used for on-line testing, and combination with a pair twister, also used for extruder production monitor, intermediate detection and finished products detection.
Direct Current (DC) spark tester Insulation Detector are regularly specified in test standards for telecommunications cables, because DC generates almost no corona and no heat, it is a gentler test and can be used to test delicate insulation with weak dielectric properties. It is also recommended for wires with foamed dielectric.
Equipment models:
ST-10C – All in one compact structure DC spark tester , 10 KV output test votage.
ST-10D – Insulation Detector Designed for online testing in combination with a pair twister, 10 KV output test votage.
ST-10S – Split structure with separate detaction head and controlor, 10 KV output test votage.
ST-15C – All in one compact structure DC spark tester, 15 KV output test votage.
ST-15S – Split structure with separate detaction head and controlor, 15 KV output test votage.
Model | ST-10C | ST-10D | ST-10S | ST-15C | ST-15S |
Output Voltage | DC 0~10 kV | DC 0~10 kV | DC 0~10 kV | DC 0~15 kV | DC 0~15 kV |
Effective Voltage | DC 0.5~10 kV | DC 0.5~10 kV | DC 0.5~10 kV | DC 0.5~15 kV | DC 0.5~15 kV |
Ratio of AC Pulse | Max 5% | Max 5% | Max 5% | Max 5% | Max 5% |
Voltage Stability | Output voltage keep stable when power supply fluctuation ± 15% | Output voltage keep stable when power supply fluctuation ± 15% | Output voltage keep stable when power supply fluctuation ± 15% | Output voltage keep stable when power supply fluctuation ± 15% | Output voltage keep stable when power supply fluctuation ± 15% |
Breakdown Sensitivity | I=600 50uA, T <= 5mS | I=600 50uA, T <= 5mS | I=600 50uA, T <= 5mS | I=600 50uA, T <= 5mS | I=600 50uA, T <= 5mS |
Current Range of breakdown Sensitivity | 0.5~2 mA | 0.5~2 mA | 0.5~2 mA | 0.5~2 mA | 0.5~2 mA |
Short Circuit Current of Steady State | 3~4 mA | 3~4 mA | 3~4 mA | 3~4 mA | 3~4 mA |
Max Counting Of Breakdown | 10 / S | 10 / S | 10 / S | 10 / S | 10 / S |
Max Wire Diameter | 10 mm | 10 mm | 10 mm | 10 mm | 10 mm |
Max Line Speed | 2800 m/S | 2800 m/S | 2800 m/S | 2800 m/S | 2800 m/S |
Power Supply | 220 VAC ± 15% ~ 50/60 Hz | 220 VAC ± 15% ~ 50/60 Hz | 220 VAC ± 15% ~ 50/60 Hz | 220 VAC ± 15% ~ 50/60 Hz | 220 VAC ± 15% ~ 50/60 Hz |
Power consumption | 50 VA | 50 VA | 50 VA | 50 VA | 50 VA |
Machine Structure | All in one compact structure | Combination with a pair twister | Split structure | All in one compact structure | Split structure |
Operating Temperature | 0 ~ 45 C |
power consumption | 50 VA |
Relative humidity | Less than 90% without condensed water |
Easy To use
Highly adaptable
Highly Sensitivity
Versatile mounting
Safety and reliability
Steady Voltage Output
Low capacitance propertiesInsulation DetectionOnline Extrusion Insulation Testing.
Online Rewinding & Testing Machine.
Online Coiling Machine.
Inspection Machine.
Used for Power Cable, Control Cable, Telephone Cable, LAN Cable, RF Cable, Automotive Wire, Building Wire.
SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.
SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…
SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.
SMC Flat Bracket Assembly ITV1000-2000-3000 Condition: New, Original or Alternate.
SMC Digital Vacuum Sensor ZSE20CF-L ZSE20CL 3 Screen IP65 with IO-Link Condition: New, Original or…
SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…
This website uses cookies.