SIPLUS MM420 FS B inverter 3 kW 6SE6420-2UD23-0BA1 6AG1420-2UD23-0BA1

6AG1420-2UD23-0BA1 SIPLUS MM420 FS B 3 kW for medial exposure based on 6SE6420-2UD23-0BA1

Sharing good things

Description

SIPLUS MM420 FS B 3 kW for medial exposure based on 6SE6420-2UD23-0BA1 6AG14202UD230BA1_datasheet_en

Technical specifications

Technical data MICROMASTER 420
Mains voltage and power ranges

 

 

200 V to 240 V 1 AC ±10 % 0.12 kW to 3 kW
200 V to 240 V 3 AC ±10 % 0.12 kW to 5.5 kW
380 V to 480 V 3 AC ±10 % 0.37 kW to 11 kW
Power frequency 47 Hz to 63 Hz
Output frequency 0 … 650 Hz, (limitation to 550 Hz in production to comply with legal requirements) 1)
Power factor ≥ 0.95
Inverter efficiency 96 % to 97 %
Overload capability Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s
Inrush current Less than rated input current
Control method Linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic (programmable V/f characteristic); flux current control (FCC)
Pulse frequency

 

16 kHz (standard with 230 V 1/3 AC)
4 kHz (standard with 400 V 3 AC)
2 kHz to 16 kHz (in 2 kHz steps)
Fixed frequencies 7, programmable
Skip frequency ranges 4, programmable
Setpoint resolution

 

 

0.01 Hz digital
0.01 Hz serial
10 bit analog
Digital inputs 3 fully programmable isolated digital inputs; switchable PNP/NPN
Analog input 1, for setpoint or PI controller (0 V to 10 V, scaleable or for use as 4th digital input)
Relay outputs 1, programmable, 30 V DC/5 A (resistive load); 250 V AC/2 A (inductive load)
Analog output 1, programmable (0 mA to 20 mA)
Serial interfaces RS-485, optional RS-232
Motor cable lengths  
  • without output choke

 

max. 50 m (shielded)
max. 100 m (unshielded)
  • with output choke
see variant dependent options
Electromagnetic compatibility

 

Inverter available with internal EMC filter Class A; available as options are EMC filters to EN 55 011, Class A or Class B
Braking DC braking, compound braking
Degree of protection IP20
Operating temperature –10 °C to +50 °C (+14 °F to +122 °F)
Storage temperature –40 °C to +70 °C (–40 °F to +158 °F)
Relative humidity 95 % (non-condensing)
Installation altitude Up to 1000 m above sea level without derating
Standard SCCR
(Short Circuit Current Rating) 2)
100 kA
Protection features for

 

 

 

 

 

 

 

 

 

Undervoltage
Overvoltage
Overload
Earth faults
Short circuit
Stall prevention
Locked motor protection
Motor overtemperature
Inverter overtemperature
Parameter interlock
Compliance with standards UL, cUL, CE, c-tick
CE marking Conformity with low-voltage directive 73/23/EEC
Cooling-air volumetric flow required, dimensions and weights
(without options)

 

 

 

Frame size (FS) Cooling-air volumetric flow required (l/s)/(CFM) H x W x D (mm)

 

 

Weight, approx. (kg)
A 4.8/10.2 173 x 73 x 149 1.0
B 24/51 202 x 149 x 172 3.3
C 54.9/116.3 245 x 185 x 195 5.0
  CFM:
Cubic Feet per Minute
   

 

Do you like this item?