SIPLUS MM420 Inverter FS B 3KW based on 6SE6420-2UD23-0BA1 6AG1420-2UD23-0BA1

6AG1420-2UD23-0BA1 SIPLUS MM420 FS B 3 kW for medial exposure based on 6SE6420-2UD23-0BA1

Sharing good things

Description

SIPLUS MM420 FS B 3 kW for medial exposure based on 6SE6420-2UD23-0BA1

Technical specifications

Technical data MICROMASTER 440
Mains voltage and power ranges CT (constant torque) VT (variable torque)
200 V to 240 V 1 AC  ±10 % 0.12 kW to 3 kW
200 V to 240 V 3 AC  ±10 % 0.12 kW to 45 kW 5.5 kW to 55 kW
380 V to 480 V 3 AC  ±10 % 0.37 kW to 200 kW 7.5 kW to 250 kW
500 V to 600 V 3 AC  ±10 % 0.75 kW to 75 kW 1.5 kW to 90 kW
Input frequency 47 Hz to 63 Hz
Output frequency in V/f mode

 

for inverter 0.12 kW to 75 kW 0 … 650 Hz, (limitation to 550 Hz in production to comply with legal requirements) 1)
for inverter 90 kW to 200 kW 0 Hz to 267 Hz
in vector mode

 

for inverter 0.12 kW to 75 kW 0 Hz to 200 Hz
for inverter 90 kW to 200 kW 0 Hz to 200 Hz
Power factor ≥ 0.95
Inverter efficiency 0.12 kW to 75 kW: 96 % to 97 %; 90 kW to 200 kW: 97 % to 98 %
Overload capability

CT mode

for inverter 0.12 kW to 75 kW Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s, and 2 x rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s
for inverter 90 kW to 200 kW Overload current 1.36 x rated output current (i.e. 136 % overload capability) for 57 s, cycle time 300 s, and 1.6 x rated output current (i.e. 160 % overload capability) for 3 s, cycle time 300 s
Overload capability

VT mode

for inverter 5.5 kW to 90 kW Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s, and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
for inverter 110 kW to 250 kW Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s, and 1.1 x rated output current (i.e. 110 % overload capability) for 59 s, cycle time 300 s
Inrush current not higher than rated input current
Control method Vector control, torque control, linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic (programmable V/f characteristic); flux current control (FCC)
Pulse frequency for inverter 0.12 kW to 75 kW 4 kHz (standard); 16 kHz (standard with 230 V inverters 0.12 kW to 5.5 kW)
2 kHz to 16 kHz (in 2 kHz steps)
for inverter 90 kW to 200 kW 2 kHz (standard with VT mode); 4 kHz (standard with CT mode)
2 kHz to 4 kHz (in 2 kHz steps)
Fixed frequencies 15, programmable
Skip frequency ranges 4, programmable
Setpoint resolution 0.01 Hz digital
0.01 Hz serial
10 bit analog
Digital inputs 6 fully programmable isolated digital inputs; switchable PNP/NPN
Analog inputs 2 programmable analog inputs

  • 0 V to 10 V, 0 mA to 20 mA and -10 V to +10 V (AIN1)
  • 0 V to 10 V and 0 mA to 20 mA (AIN2)
  • both can be used as 7th/8th digital input
Relay outputs 3, programmable
30 V DC/5 A (resistive load)
250 V AC/2A (inductive load)
Analog outputs 2, programmable (0/4 mA to 20 mA)
Serial interfaces RS-485, optional RS-232
Motor cable lengths Without output choke for inverter 0.12 kW to 75 kW max. 50 m (shielded)
max. 100 m (unshielded)
for inverter 90 kW to 250 kW max. 200 m (shielded)
max. 300 m (unshielded)
With output choke see variant dependent options
Electromagnetic compatibility (see Selection and Ordering Data) EMC filter, Class A or Class B to EN 55 011 available as an option
Inverter with internal filter Class A available
Braking Resistance braking with DC braking, compound braking, integrated brake chopper (integrated brake chopper only with 0.12 kW to 75 kW inverters)
Degree of protection IP20
Operating temperature (without derating) for inverter 0.12 kW to 75 kW CT: -10 °C to +50 °C (+14 °F to +122 °F)
VT: -10 °C to +40 °C (+14 °F to +104 °F)
for inverter 90 kW to 200 kW 0 °C to +40 °C (+32 °F to +104 °F)
Storage temperature -40 °C to +70 °C (-40 °F to +158 °F)
Relative humidity 95 % (non-condensing)
Installation altitude for inverter 0.12 kW to 75 kW up to 1000 m above sea level without derating
for inverter 90 kW to 200 kW up to 2000 m above sea level without derating
Standard SCCR
(Short Circuit Current Rating) 2)
FSA, FSB, FSC: 100 kA
FSD, FSE, FSF, FSFX, FSGX: 65 kA
Protection features for Undervoltage, overvoltage, overload, earth faults, short-circuits, stall prevention, locked motor protection, motor overtemperature, inverter overtemperature, parameter change protection
Compliance with standards uL, c uL, CE, c-tick
CE marking Conformity with low-voltage directive 73/23/EEC
Cooling-air volumetric flow required, dimensions and weights (without options) Frame size (FS) Cooling-air volumetric flow required (l/s)/(CFM) H x W x D, max. (mm) Weight, approx. (kg)
A 4.8/10.2 173 x 73 x 149 1.3
B 24/51 202 x 149 x 172 3.4
C 54.9/116.3 245 x 185 x 195 5.7
D 2 x 54.9/2 x 116.3 520 x 275 x 245 17
E 2 x 54.9/2 x 116.3 650 x 275 x 245 22
F without filter 150/317.79 850 x 350 x 320 56
F with filter 150/317.79 1150 x 350 x 320 75
FX 225/478.13 1400 x 326 x 356 116
GX 440/935 1533 x 326 x 545 174
CFM:
Cubic Feet per Minute
 

 