SIMATIC S7-1500 Communication SIPLUS CM PtP 6AG1541-1AD00-7AB0

SIPLUS S7-1500cm PtP RS232 HF -40…+70 °C Start-up -25 °C with conformal coating based on 6ES7541-1AD00-0AB0 . Communication module for Serial connection RS232, Freeport, 3964 (R), USS, MODBUS RTU Master, Slave, 115200 Kbit/s, 9-pin D-sub connector

Sharing good things

Description

SIPLUS S7-1500cm PtP RS232 HF -40…+70 °C Start-up -25 °C with conformal coating based on 6ES7541-1AD00-0AB0 . Communication module for Serial connection RS232, Freeport, 3964 (R), USS, MODBUS RTU Master, Slave, 115200 Kbit/s, 9-pin D-sub connector 6AG15411AD007AB0_datasheet_en

Application of S7-1500 IO Modul CM PtP

Communication modules enable the connection with an external communication partner to exchange data. Comprehensive parameterization options make it possible to adapt the control flexibly to the communication partner. 
Modbus RTU master creates a Modbus RTU network for up to 30 Modbus slaves.

The following communication modules are available:

  • CM PtP RS232 BA; 
    communication module with RS232 interface for the protocols Freeport, 3964(R) and USS; 9-pin sub D connector, max. 19.2 Kbit/s, 1 KB frame length, 2 KB receive buffer
  • CM PtP RS232 HF; 
    communication module with RS232 interface for the protocols Freeport, 3964(R), USS and Modbus RTU; 9-pin sub D connector, max. 115.2 Kbit/s, 4 KB frame length, 8 KB receive buffer
  • CM PtP RS422/485 BA; 
    communication module with RS422 and RS485 interface for the protocols Freeport, 3964(R) and USS; 15-pin sub D socket, max. 19.2 Kbit/s, 1 KB frame length, 2 KB receive buffer
  • CM PtP RS422/485 HF; 
    communication module with RS422 and RS485 interface for the protocols Freeport, 3964(R), USS and Modbus RTU; 15-pin sub D socket, max. 115.2 Kbit/s, 4 KB frame length, 8 KB receive buffer
  • Modules for serial communication connections, scaled according to interface types, protocols, and performance
  • 4 versions with different physical transmission characteristics:
    • RS 232C, max. 19.2 Kbit/s
    • RS 232C, max.115.2 Kbit/s
    • RS 422/RS 485, max. 19.2 Kbit/s
    • RS 422/RS 485, max. 115.2 Kbit/s
  • Protocols supported
    • Freeport: User-parameterizable telegram format for universal communication
    • 3964(R) for improved transmission reliability
    • Modbus RTU Master
    • Modbus RTU Slave
    • USS, implemented through instructions

Do you like this item?

Drop us a line by compiling the form below. We will be more than happy to reply to any of your inquiry!