SIMATIC S7-1500 PLC CPU 1518-4 PN/DP 6ES7518-4AP00-0AB0

SIMATIC S7-1500, CPU 1518-4 PN/DP, Central processing unit with work memory 4 MB for program and 20 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: Ethernet, 4th interface: PROFIBUS, 1 ns bit-performance, SIMATIC Memory Card required

6ES75184AP000AB0_datasheet_en

S7-1500 PLC Standard CPU list

Characteristics CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN CPU 1516-3 PN/DP CPU 1517-3 PN/DP CPU 1518-4 PN/DP CPU 1518-4 PN/DP ODK
Work memory for program, integrated 150 KB 300 KB 500 KB 1 MB 2 MB 4 MB 4 MB
Work memory for data, integrated 1 MB 1.5 MB 3 MB 5 MB 8 MB 20 MB 20 MB, additional 20 MB for ODK
Load memory Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card
Display diagonal 3.45 cm 3.45 cm 6.1 cm 6.1 cm 6.1 cm 6.1 cm 6.1 cm
Command execution times
  • Bit operations
0.06 μs 0.04 μs 0.03 μs 0.01 μs 0.002 μs 0.001 μs 0.001 μs
  • Word operations
0.072 μs 0.048 μs 0.036 μs 0.012 μs 0.003 μs 0.002 μs 0.002 μs
  • Fixed-point operations
0.096 μs 0.064 μs 0.048 μs 0.016 μs 0.003 μs 0.002 μs 0.002 μs
  • Floating-point operations
0.384 μs 0.256 μs 0.192 μs 0.064 μs 0.012 μs 0.006 μs 0.006 μs
Bit memories, timers, counters
S7 counters/timers 2048 each 2048 each 2048 each 2048 each 2048 each 2048 each 0.001 μs
IEC counters Any number (only limited by the work memory)
IEC timers Any number (only limited by the work memory)
Bit memories 16 KB 16 KB 16 KB 16 KB 16 KB 16 KB 0.002 μs
I/O address range
Inputs 32 KB (all inputs are stored in the process image)
Outputs 32 KB (all outputs are stored in the process image)
Motion control
Typical number of positioning axes (at 4 ms servo/IPO cycle) 5 5 7 7 70 128 128
Max. number of positioning axes 10 10 30 30 128 128 128
Communication
PtP CM) Yes (via CM) Yes (via CM) Yes (via CM) Yes (via CM) Yes (via CM) Yes (via CM)
PROFINET IO RT Yes (via CM) Yes (via CM) 1 x PN IO RT (and via CM) 1 x PN IO RT (and via CM) 1 x PN IO RT (and via CM) 1 x PN IO RT,
1 x PN (and via CM)
1 x PN IO RT,
1 x PN (and via CM)
PROFINET IO IRT 1 x PN IO IRT
(2-port switch)
1 x PN IO IRT
(2-port switch)
1 x PN IO IRT (2-port switch) 1 x PN IO IRT
(2-port switch)
1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch)
PROFIBUS Yes (via CM) Yes (via CM) Yes (via CM) 1 x DP (and via CM) 1 x DP (and via CM) 1 x DP (and via CM) 1 x DP (and via CM)
OPC UA DA server Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required)
Web server Yes Yes Yes Yes Yes Yes Yes

Application

Five standard CPUs with differing performance ranges are available for SIMATIC S7-1500:

  • CPU 1511-1 PN:
    for smaller applications with medium requirements on the program scope and processing speed, for distributed setup via PROFINET IO.
  • CPU 1513-1 PN:
    for applications with medium requirements on the program scope and processing speed, for distributed setup via PROFINET IO.
  • CPU 1515-2 PN:
    for applications with medium/high requirements on the program scope, networking and processing speed, for distributed setup via PROFINET IO. The second PROFINET interface with separate IP address can be used for connecting further PROFINET IO RT devices, for high-speed communication as an I-Device, or for network separation.
  • CPU 1516-3 PN/DP:
    for applications with high requirements regarding program scope, networking and processing speed, for distributed setup via PROFINET IO and PROFIBUS DP. The second PROFINET interface with separate IP address can be used for connecting further PROFINET IO RT devices, for high-speed communication as an I-Device, or for network separation.
  • CPU 1517-3 PN/DP:
    for applications with very high requirements regarding program scope and networking, and for very high requirements regarding processing speed, for distributed setup via PROFINET IO and PROFIBUS DP. The second PROFINET interface with separate IP address can be used for connecting further PROFINET IO RT devices, for high-speed communication as an I-Device, or for network separation.
  • CPU 1518-4 PN/DP:
    for applications with extremely high requirements regarding program scope and networking, and for maximum requirements regarding processing speed. For distributed configuration via PROFINET IO and PROFIBUS DP. The PROFINET interface X2 can be used for connecting additional PROFINET IO RT devices or for fast communication as an I-Device. The PROFINET interface X3 gives you the capability of transferring data at a speed of 1 Gbit/s. The two additional integrated PROFINET interfaces with separate IP address can be used for network separation, for example.
  • CPU 1518-4 PN/DP ODK:
    for applications with very high requirements regarding program scope, networking and processing speed and for maximum requirements regarding processing speed. For distributed configuration via PROFINET IO and PROFIBUS DP. The PROFINET interface X2 can be used for connecting additional PROFINET IO RT devices or for fast communication as an I-Device. The PROFINET interface X3 gives you the capability of transferring data at a speed of 1 Gbit/s. The two additional integrated PROFINET interfaces with separate IP address can be used for network separation, for example. The CPU 1518-4 PN/DP ODK allows the execution of functions created with the high-level language C/C++.

Application of S7-1500 PLC

The SIMATIC S7-1500 is the modular control system for a variety of automation applications in discrete automation.

The modular and fan-free design, simple implementation of distributed structures, and convenient handling make the SIMATIC S7-1500 the cost-effective and user-friendly solution for the most diverse tasks.

Application areas of the SIMATIC S7-1500 include:

  • Special machines
  • Textile machines
  • Packaging machines
  • Pick-and-place machines
  • Assembly machines
  • Palleting machines
  • General mechanical engineering
  • Controller building
  • Machine tool manufacture
  • Installation systems
  • Electrical/electronics industry and the skilled trades
  • Automotive
  • Water/wastewater
  • Food & beverage

Several CPUs of different performance levels and a comprehensive module range with many convenient functions are available. Failsafe CPUs facilitate use in failsafe applications. The modular design allows users to use only the modules they require for their applications. In the case of task expansions, the controller can be upgraded at any time by means of additional modules:

High industrial strength thanks to high electromagnetic compatibility and high resistance to shock and vibration enable universal use of the SIMATIC S7-1500.

General technical specifications

Degree of protection
IP20 acc. to IEC 60 529
Ambient temperature

  • Horizontal installation

0…60 °C (display: at an operating temperature of typ. 50 °C, the display is switched off.)

  • Vertical installation

0… 40 °C (display: at an operating temperature of typ. 40 °C, the display is switched off.)

Relative humidity

10%…95%, no condensation

Atmospheric pressure

From 1080 to 795 hPa
(corresponds to an altitude of -1000 to +2000 m)

Insulation

  • < 50 V

707 V DC test voltage (type test)

  • < 150 V

2200 V DC test voltage

  • < 250 V

2500 V DC test voltage

Electromagnetic compatibility

Requirements of the EMC directive;
interference immunity according to IEC 61000-6-2

  • Pulse-shaped disturbance variables

Test according to:
Electrostatic discharge according to IEC 61000-4-2,
burst pulses according to IEC 61000-4-4,
energy single pulse (surge) according to IEC 61000-4-5,

  • Sinusoidal disturbance variables

Test according to:
HF irradiation according to IEC 61000-4-3,
HF decoupling according to IEC 61000-4-6

Requirements of the EMC directive;
interference emission according to EN 61000-6-4

  • Emission of radio frequency interference

Interference emission according to 61000-6-4

Interference emission of electromagnetic fields according to EN 61000-6-4

Mechanical stress

  • Vibrations

Testing according to EN 60068-2-6
Tested with:
5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 7 mm;
9 Hz ≤ f ≤ 150 Hz, constant acceleration 2 g;
duration of vibration: 10 frequency passes per axis in each direction of the 3 mutually perpendicular axes

  • Shock

Testing according to EN 60068-2-27
Tested with:
Half-wave:
strength of shock 15 g peak value, 11 ms duration;
shock direction: 3 shocks each in ± direction in each of the 3 mutually vertical axes

 

 

Editor

Share
Published by
Editor

Recent Posts

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ITV1000 2000 3000 Flat Bracket Assembly

SMC Flat Bracket Assembly ITV1000-2000-3000 Condition: New, Original or Alternate.

2 years ago

ZSE20C(F)-L Digital Vacuum Sensor 3 Screen IP65 with IO-Link

SMC Digital Vacuum Sensor ZSE20CF-L ZSE20CL 3 Screen IP65 with IO-Link Condition: New, Original or…

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

This website uses cookies.