SIMATIC S7-1500F PLC S7-1516F-3 PN/DP 6ES7516-3FN01-0AB0

SIMATIC S7-1500F, CPU 1516F-3 PN/DP, Central processing unit with work memory 1.5 MB for program and 5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 10 ns bit performance, SIMATIC Memory Card required 6ES75163FN010AB0_datasheet_en

Fail-safe CPUs for SIMATIC S7-1500

Characteristics CPU 1511F-1 PN CPU 1513F-1 PN CPU 1515F-2 PN CPU 1516F-3 PN/DP CPU 1517F-3 PN/DP CPU 1518F-4 PN/DP CPU 1518F-4 PN/DP MFP
Work memory for program, integrated 225 KB 450 KB 750 KB 1.5 MB 3 MB 6 MB 6 MB
Work memory for data, integrated 1 MB 1.5 MB 3 MB 5 MB 8 MB 20 MB 20 MB, additional 50 MB for CPU function library
Load memory Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card Plug-in via SIMATIC Memory Card
Command execution times
· Bit operations 0.06 μs 0.04 μs 0.03 μs 0.01 μs 0.002 μs 0.001 μs 0.001 μs
· Word operations 0.072 μs 0.048 μs 0.036 μs 0.012 μs 0.003 μs 0.002 μs 0.002 μs
· Fixed-point operations 0.096 μs 0.064 μs 0.048 μs 0.016 μs 0.003 μs 0.002 μs 0.002 μs
· Floating-point operations 0.384 μs 0.256 μs 0.192 μs 0.064 μs 0.012 μs 0.006 μs 0.006 μs
Integral interfaces
PROFINET IO IRT 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch) 1 x PN IO IRT (2-port switch)
PROFINET 1 x PN 1 x PN 1 x PN 2 x PN 2 x PN
PROFIBUS DP 1 x DP 1 x DP 1 x DP 1 x DP
OPC UA DA server Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required) Yes (RT license required)
Standards, approvals, certificates SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

SIL according to IEC 61508: to SIL3 in each case

PL according to ISO 13849: to PLe in each case

Application

Various failsafe CPUs with graduated levels of performance are available for the SIMATIC S7-1500:

  • CPU 1511F-1 PN:
    the cost-effective entry-level CPU for standard and fail-safe applications with medium requirements in terms of processing performance and response speed in discrete production technology.
  • CPU 1513F-1 PN:
    the CPU with a medium to large program and data memory for standard and fail-safe applications that also include distributed automation structures alongside central I/O.
  • CPU 1515F-2 PN:
    for standard and failsafe applications with medium/high requirements for program scope and processing speed, for distributed setup via PROFINET IO with PROFIsafe.
  • CPU 1516F-3 PN/DP:
    for applications with medium/high requirements for program scope and processing speed, for distributed configuration via PROFINET IO and PROFIBUS DP with PROFIsafe.
  • CPU  1517F-3 PN/DP:
    for standard and failsafe applications with very high requirements for program scope networking, and for very high requirements regarding processing speed, for distributed setup via PROFINET IO and PROFIBUS DP with PROFIsafe. The additional integrated PROFINET interface with separate IP address can be used for network separation, for example.
  • CPU 1518F-4 PN/DP:
    for standard and failsafe applications with high requirements for program scope and processing speed, for distributed setup via PROFINET IO and PROFIBUS DP with PROFIsafe. The additional integrated PROFINET interface with separate IP address can be used, for example, for network separation.
Editor

Share
Published by
Editor

Recent Posts

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ITV1000 2000 3000 Flat Bracket Assembly

SMC Flat Bracket Assembly ITV1000-2000-3000 Condition: New, Original or Alternate.

2 years ago

ZSE20C(F)-L Digital Vacuum Sensor 3 Screen IP65 with IO-Link

SMC Digital Vacuum Sensor ZSE20CF-L ZSE20CL 3 Screen IP65 with IO-Link Condition: New, Original or…

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

This website uses cookies.