SIPLUS S7-400 Y-coupler 6AG1197-1LB00-4XA0

SIPLUS S7-400 Y-coupler for medial exposure based on 6ES7197-1lb00-0XA06AG11971LB004XA0_datasheet_en

Overview

  • Bus coupler for transition from a redundant PROFIBUS DP master system to a single-channel PROFIBUS DP master system
  • For connection of devices with only one PROFIBUS DP interface to the redundant PROFIBUS DP master system of the SIMATIC S7-400H

Application

The Y-link is a bus coupler for transition from a redundant PROFIBUS master system to a single-channel PROFIBUS DP master system. This means that devices with only one PROFIBUS DP interface can be connected to an S7-400H as switched peripherals.

 

Design

The Y-link comprises:

  • 2 IM 153-2 High Feature Outdoor interface modules
  • 1 Y coupler
  • 1 BM IM/IM bus module
  • 1 BM Y-coupler bus module

Snapped on mounting rails for setup with active bus modules.

Configuration options and limitations

A redundant PROFIBUS DP master system can be extended by means of Y-links in the following way:

  • The number of Y-links on a redundant DP master system is only limited by the maximum number of stations. The maximum number of connectable slaves depends on the length of the user data and configuration message frames. The total length of each may not exceed 244 bytes (see slave technical data). Generally, the following applies:
    • Max. 64 stations in the lower-level DP master system
    • Max. 236 slots in the lower-level DP master system
  • Y-link configuration and user data message frames comprise message frame contents of the lower-level slaves. The maximum frame length is therefore 244 bytes.
  • Direct communication and equidistance not possible in the lower-level master system

 

Function

Y-link

  • Transmission rates for the redundant master system:
    9.6 Kbit/s to 12 Mbit/s
  • Bumpless switchover of the redundant PROFIBUS DP master system’s active channel.
  • Supports system changes on a SIMATIC S7-400H during operation
  • Diagnostics via LEDs and the user program

Y coupler

  • Transmission rates for the lower-level master system (independent of redundant DP master system):
    187.5 Kbit/s to 12 Mbit/s
  • Electrical isolation between lower-level DP master system and power supply via the coupler
  • IP20 degree of protection
Principle of operation

The Y-link maps the lower-level DP master system on the redundant PROFIBUS DP master system as a switched PROFIBUS DP slave .

The Y coupler and the lower-level DP master system form an independent bus system and operate decoupled from the redundant bus system.

The Y-link as a DP slave on the redundant DP master system acts as a proxy for the stations on the lower-level DP master system with regard to data.

Configuration

The Y-link can be configured with STEP 7 as of Version 5.4. It is not necessary to configure the Y coupler.

When STEP 7 calculates the bus parameters, the stations connected on the lower-level DP master system as well as the Y-link itself are taken into account.

Parameter assignment of the DP slaves

The redundant DP master system assigns the parameters for the DP slaves in the lower-level DP master system via the Y-link.

   

Editor

Share
Published by
Editor

Recent Posts

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

VX3x Direct Operated 3 Port Solenoid Valve for Manifold

SMC Direct Operated 3 Port Solenoid Valve VX3x for Manifold Condition: New, Original or Alternate.

2 years ago

ITV1000 2000 3000 Flat Bracket Assembly

SMC Flat Bracket Assembly ITV1000-2000-3000 Condition: New, Original or Alternate.

2 years ago

ZSE20C(F)-L Digital Vacuum Sensor 3 Screen IP65 with IO-Link

SMC Digital Vacuum Sensor ZSE20CF-L ZSE20CL 3 Screen IP65 with IO-Link Condition: New, Original or…

2 years ago

ZSE20C(F) Digital Vacuum Sensor 3 Screen 2 Output + Analog IP65

SMC Digital Vacuum Sensor ZSE20CF ZSE20C 3 Screen 2 Output + Analog IP65 Condition: New,…

2 years ago

This website uses cookies.