PF3W7-X365 is an application specific version of the standard PF3W7 with
SUS316 stainless steel compression fittings in place of the threaded pipe
adapters. Further refinements include EPDM seals, as well as double
O-rings when the optional flow adjustment valve is selected. These
upgrades allow for the measurement of the flow of fluorinated liquids such
as Fluorinert™ or GALDEN®, preferred coolants in the semiconductor
industry. Fewer flow ranges are offered, and no remote version. Some
temperature and liquid restrictions apply. PF3W-X365 is IP65 rated, and
C-UL-US, CE, and RoHS compliant.
– Flow ranges (lpm): 0.5-4, 2-16, 5-40
– Fitting sizes: TSJ3/8, TSJ1/2 (flow range dependent)
– Temperature rating: 0-90°C
– Output options: NPN/PNP, 1-5V, 4-20mA
– Accuracy: ±3% F.S.
– Repeatability: ±2% F.S.
Download PF3W7-X365 Datasheet by click the link Datasheet.